Differential-pressure method, resolution 0.01 Pa (24-bit)
Accuracy up to FS 0.05 %, range ±500 … ±10 000 Pa
In-house high-pressure pneumatic sealing valve for stable readings
Test pressure 0 – 3500 kPa; driving air 0.4 – 0.6 MPa
7-inch touch screen, 40 parameter sets, 128 MB test memory
RS232 / RS485 / RJ45 (Modbus TCP); PROFINET / PROFIBUS optional

Overview

The MSF-F115K measures leak rate by the differential-pressure method. The part and a reference sample are pressurised together; the valve then closes and any leakage in the part shows up as a small pressure difference between the two circuits. Because both circuits sit in the same environment, ambient temperature drift acts on both of them equally and cancels out – which is why this method holds a stable reading on small leaks and on large parts.

Key features

  • Resolution 0.01 Pa – resolves leaks that a 1 Pa direct-pressure instrument cannot see
  • Accuracy up to FS 0.05 % over a ±500 … ±10 000 Pa span
  • Independently developed high-pressure pneumatic sealing valve – the valve is usually the source of drift on cheaper benches
  • Little influence from outside fluctuation, so readings stay repeatable across a shift
  • Multiple communication interfaces, multiple languages, dual password protection

How the measurement works

Reference and test circuits are filled at the same time, then the pneumatic shut-off valve closes. If the part leaks, the pressure in the test circuit falls; a differential-pressure sensor measures the resulting difference between the reference and the test circuit. Since both circuits are exposed to the same ambient conditions, external influences cancel out and precision improves.

Differential pressure method: reference and test circuit with a differential pressure sensor
Differential pressure method: reference and test circuit with a differential pressure sensor

Technical data

Sensor accuracyFS 0.05 %
Resolution0.01 Pa (24-bit)
Measuring range±500 … ±10 000 Pa
Test pressure0 – 3500 kPa
Drive gas pressure0.4 – 0.6 MPa (driving pressure should be 0.1 MPa above the test pressure)
Pressure unitsPa, kPa, MPa, bar, PSI, kgf/cm², atm, mmHg
Leak-rate unitsPa, kPa, mbar, SCCM, CCM/s, Pa·m³/s
Display7-inch HD colour resistive touch screen
Parameter sets40
Time setting0 – 99 999.9 s
Serial communicationRS485 / RS232 (optional)
Network communicationRJ45 (Modbus TCP) standard; PROFINET / PROFIBUS optional
USB interfaceUSB 2.0 – test record download, CSV format
Memory30-day test record, 128 MB
LanguageChinese / English
Environment0 – 50 °C
Power supply100 – 240 VAC, 60 W
DimensionsL 320 × W 360 × H 165 mm
Weightapprox. 7 kg
External control input4 sets of PNP input signals
External control output4 high-level outputs
Pressure regulationMechanical (standard) / electronic (optional)

Typical applications

  • Automotive parts – connectors, sensors, castings
  • Power-battery packs and cooling circuits
  • Medical devices – catheters, IV sets, blister packs
  • Valves, fittings and pipe assemblies
  • 3C electronics and smart wearables