Mass-flow measurement, resolution 0.01 sccm
Sensor accuracy FS 1 %, range 0.1 – 1000 ml/min
Reads the leak directly as a flow rate – no waiting for pressure decay
For open or continuously leaking parts
Widely used for EV battery packs, motors, controller housings and cooling circuits
7-inch touch screen, 40 parameter sets, RS232 / RS485 / RJ45

Overview

The MSF-L135K measures the leak as a flow rate instead of a pressure drop. Air passing through the leak is led through a flow meter, so the reading is direct and fast – and it stays valid on parts that are open to atmosphere or that leak continuously, where a pressure-decay test would never build pressure at all.

Key features

  • Mass-flow detection principle – high-precision flow measurement
  • Multiple test ranges covering 0.1 – 1000 ml/min
  • Direct leak-rate reading: no decay curve to interpret
  • Suited to open volumes, porous parts and continuous leaks
  • Widely used for water-proof testing of new-energy vehicle components, power batteries, motors, controller housings and water-cooling systems

How the measurement works

The part is filled with air to the set pressure and the flow valve closes. If the part leaks, gas passes from the reference side through the flow sensor towards the test side, and the sensor reads that flow directly – which is the leak rate.

Flow method: leak rate measured as mass flow through a flow sensor
Flow method: leak rate measured as mass flow through a flow sensor

Technical data

Sensor accuracyFS 1 %
Resolution0.01 sccm (24-bit)
Measuring range0.1 – 1000 ml/min
Test pressure0 – 3500 kPa
Drive gas pressure0.4 – 0.8 MPa (driving pressure should be 0.1 MPa above the test pressure)
Pressure unitskPa, bar, Pa, PSI, mmHg, mmH₂O, MPa, mbar, kgf/cm², atm
Flow-rate unitsin³/d, cm³/min, cm³/s, cm³/h, mm³/s, ml/s, ml/min, ml/h, g/s, g/min, g/h, SCCM, accm
Display7-inch HD colour resistive touch screen
Parameter sets40
Time setting0 – 99 999.9 s
Serial communicationRS485 / RS232 (optional)
Network communicationRJ45 (Modbus TCP) standard; PROFINET / PROFIBUS optional
USB interfaceUSB 2.0 – test record download, CSV format
Memory30-day test record, 128 MB
LanguageChinese / English
Environment0 – 50 °C
Power supply100 – 240 VAC, 60 W
DimensionsL 320 × W 360 × H 165 mm
Weightapprox. 7 kg
External control input4 sets of PNP input signals
External control output4 high-level outputs
Pressure regulationMechanical (standard) / electronic (optional)

Typical applications

  • EV battery packs and water-cooling circuits
  • Motors and controller housings
  • Filters, porous parts and sintered components
  • Open or vented assemblies
  • Production lines needing a very short cycle

RELATED PRODUCTS