Measuring range up to 60 MPa
Temperature compensation (0–70 °C)
316L stainless steel housing
Diaphragm overload protection
Pure flat diaphragm design

Ask for a price

The GP-2210 Flush Diaphragm Pressure Sensor integrates a high-quality MEMS sensing element with advanced temperature compensation and digital output correction to ensure excellent accuracy and stability.

Each sensor is individually calibrated and compensated over the operating temperature range, providing reliable performance in demanding industrial environments.

The pure flat diaphragm with rear-threaded structure eliminates dead zones and prevents medium accumulation, making installation and cleaning fast and simple. This design makes the GP-2210 especially suitable for hygienic processes, viscous fluids, and applications in food, pharmaceutical, and sanitary industries.

With its wide pressure range and robust 316L stainless steel housing, the GP-2210 delivers long-term reliability for critical process monitoring.

ItemParameter
Housing316L Stainless Steel
PinGolden Covar Pin / Silicon Wires
O-ringFKM
Power Supply≤2.0mA DC
Input Resistance2.5kΩ~5kΩ
Output Resistance2.5kΩ~5kΩ
Response Time(10%~90%):<1ms
Isolation100MΩ, 100V DC
Over Pressure3x(Range≤100kPa) 2x(Range≥200kPa)
Burst Pressure5x(Range<10MPa) 3x(Range≥10MPa)
MediumGas or Liquid
Vibration10gRMS, (20~2000)Hz
Shock100g, 11ms
Position EffectAny angle≤90°,Zero Drift≤±0.01%FS
Standard ConditionMedia temperature:25±1℃
Environment temperature: 25±1℃
Humidity: 50%±10%RH
Environment pressure: 86~106kPa
Power supply: 1.5±0.0015mA DC
ItemMin.Typ.Max.Unit
Linearity±0.15±0.25 ①%FS, BFSL
Repeatability±0.05±0.075%FS
Hysteresis±0.1%FS
Zero Output±2mV DC
Full Scale Output45100mV DC
Compensation Temperature0~70℃
Operating Temperature-40~125℃
Storage Temperature-55~150℃
Zero Temperature Error±0.75±1.0%FS, @25℃
F ull Temperature Error±0.75±1.0%FS, @25℃
Long-term stability±0.2%FS/Year
Remarks:
1. The above performance was valued under standard conditions.
2. Temperature drift test temperature range is the compensation temperature range.

RELATED PRODUCTS

GP-2211 Flush Diaphragm Pressure Sensor

Measuring range up to 35 MPa Food-grade oil-filled isolation 316L stainless steel housing Flat diaphragm overload protection G1/4 thread with flush membrane

GP-2301 Hygienic Pressure Sensor

Flush diaphragm for hygienic processes 1.4435 stainless steel, polished surface DIN 11851 hygienic process connection AK100 safety silicone oil filling Temperature-compensated MEMS chip Laser-trimmed signal correction

Applications & solutions

Technical articles where this product is used

RELATED PRODUCTS