LF3000 Microfluidic Flow Meter

Microfluidic thermal time-of-flight flow meter
Full scale from 500 µL/min to 500 mL/min
Accuracy ±(2.0+0.5FS) %, dead volume < 7 µL
I2C, 0.5 ~ 4.5 Vdc, RS485 or 4 ~ 20 mA output
UNF 1/4-28 or NPT 1/8 connection, IP67
PEEK/SiNx or PPS/SiNx wetted path, OLED display

FMVH-016-2AO-G12 4-20 mA Vortex Flow Sensor

Vortex flow sensor, 1–16 L/min (0.06–0.96 m³/h) Port sizes G1/2, G3/4, G1; ranges up to 150 L/min Two 4-20 mA outputs, flow and temperature M12 A-coded 4-pin connector, 24 VDC supply TFT colour display, four viewing directions 12 bar, 18 bar max., IP65, water

FMVH-016-IOL-G12 IO-Link Vortex Flow Sensor

Vortex flow sensor, 1–16 L/min (0.06–0.96 m³/h) Port sizes G1/2, G3/4, G1; ranges up to 150 L/min Flow and temperature switching outputs, dual display IO-Link Class A, M12 A-coded 4-pin connector TFT colour display, four viewing directions NPN/PNP/push-pull, NO/NC, 12 bar, IP65

GF-X5 Clamp-on Ultrasonic Flow Sensor

±1.5% high accuracy
Non-invasive, hygienic measurement
No clogging, low pressure loss
4-line IPS LCD display
Flow and temperature bar graph
Button-based menu operation

PLSN Thermal Flow Sensor

Calorimetric detection principle Flow and temperature alarm function Digital LED display with mirroring Programmable via 3 buttons 360° rotatable housing M18 × 1.5 internal thread PNP normally open output M12 electrical connector

PLSU Thermal Flow Sensor

Thermal conductivity detection principle Insertion-type flow measurement LED flow status indicator Adjustable switching point Full stainless steel housing Multiple process connection sizes Suitable for water and oil monitoring

PLSX Thermal Flow Sensor

Thermal conductivity detection principle LED flow status indication Adjustable switching point Plastic or stainless steel housing Multiple process connections Suitable for liquid and gas monitoring

FMV IO-Link Vortex Flow Sensor

Flow,Temperature dual switches Range: 5-40L/min NPN/PNP/push-pull optional High-resolution lPS display Cumulative flow recording function Various thread & model selections Simple button menu operation Four viewing directions

GF-AM1 Electromagnetic Flow Sensor

Flow range: 3 L/h to 40 m³/h Velocity range: 0.01–10 m/s Accuracy: ±0.5% RS Repeatability: 1/3 of accuracy Media conductivity ≥20 µS/cm Working pressure: up to 1.6 MPa Max temperature: 70 °C Protection class: IP65

GF-KS Clamp-on Ultrasonic Flow Sensor

Clamp-on, non-invasive installation ±1.0% measurement accuracy Integrated signal processing Bubble and particle detection Bi-directional flow measurement No pressure loss or blockage

GF-KG Clamp-on Ultrasonic Flow Sensor

High precision & stability
Non-contact measurement
Bi-directional, volume & bubble detection
Embedded circuitry, no external system
No blockage, low pressure loss
Standard outputs for integration

Liquid Flow Meters — clamp-on ultrasonic, electromagnetic, vortex and thermal

Liquid flow in existing pipework is usually measured from outside or through a short in-line section. This group collects the four principles we supply: clamp-on ultrasonic meters that need no pipe cutting, electromagnetic meters for conductive liquids, vortex meters for a compact in-line point, and thermal sensors for low-flow monitoring.

The choice is driven by pipe size, conductivity, temperature, required accuracy and whether the pipe may be opened. Each product page lists the manufacturer’s technical data; the datasheet adds dimensions, process connections and ordering codes. Models with IO-Link report flow and diagnostics over the same cable used for the control system.