Product categories
FMVH-016-IOL-G12 IO-Link Vortex Flow Sensor
Vortex flow sensor, 1–16 L/min (0.06–0.96 m³/h)
Port sizes G1/2, G3/4, G1; ranges up to 150 L/min
Flow and temperature switching outputs, dual display
IO-Link Class A, M12 A-coded 4-pin connector
TFT colour display, four viewing directions
NPN/PNP/push-pull, NO/NC, 12 bar, IP65
The FMVH-016-IOL-G12 is a vortex flow sensor for water in pipes. It measures flow and medium temperature in one housing, shows both on a TFT colour display, and switches two outputs that can be assigned to either value. The electrical side is a single M12 A-coded connector carrying 24 VDC and an IO-Link Class A interface.
A bluff body in the flow path sheds vortices at a frequency proportional to velocity — the von Karman vortex street — and the electronics turn that frequency into litres per minute. Switch point, reset point, hysteresis or window mode, NPN/PNP/push-pull and normally open or closed are all set from the three front buttons, and the display can be turned to four viewing directions. An accumulated flow counter adds up the volume since power-up; it is intended for reference and resets when the sensor is switched off. Depending on the upstream fitting, the sensor needs 15–50 DN of straight pipe before it and 5 DN after it.
The G1/2 female thread carries 1–16 L/min. The same sensor is built in five ranges up to 150 L/min with G1/2, G3/4 and G1 ports, so dosing lines and cooling circuits can be covered by one family. Wetted parts are ETFE, PA6T and 304 stainless steel, the body is rated 12 bar continuous and 18 bar maximum, and IP65 allows installation in machine tools, water treatment and process cooling. Ambient range is −10 to 65 °C.
| Model | FMVH-016-IOL-G12 |
|---|---|
| Operating voltage | 24 VDC ± 10 % |
| Operating current | < 100 mA |
| Ambient temperature | −10 … 65 °C |
| Ingress protection rating | IP65 |
Flow parameters
| Measured medium | Water |
|---|---|
| Measuring range | 1–16 L/min (0.06–0.96 m³/h) |
| Flow accuracy | < 3.0 % F.S. |
| Accumulated flow range | 99 999 L or 99 999 m³ (resets after power-off; for reference only) |
| Wetted materials | ETFE / PA6T / SUS 304 stainless steel |
| Process connection | G1/2 female thread |
| Pressure rating | 12 bar; maximum pressure 18 bar |
| Real-time flow unit | L/min or m³/h, selectable by button |
| Switching output type | NPN/PNP/push-pull, NO/NC, hysteresis/window, programmable |
| Switching output current | 250 mA |
| Switch point SP setting range | 1.2–16 L/min |
| Reset point rP setting range | 1–15.8 L/min |
| Minimum separation between SP and rP | 0.2 L/min |
| Switching output resolution | 0.1 L/min |
Temperature parameters
| Measuring range | 0–100 °C |
|---|---|
| Temperature accuracy | 1 °C |
| Display unit | °C or °F, selectable by button |
| Switching output type | NPN/PNP/push-pull, NO/NC, hysteresis/window, programmable |
| Switching output current | 250 mA |
| Switch point SP setting range | 1–100 °C |
| Reset point rP setting range | 0–99 °C |
| Minimum separation between SP and rP | 1 °C (1 % F.S.) |
| Switching output resolution | 0.1 °C |
IO-Link
| Number of interfaces | 1 |
|---|---|
| IO-Link protocol version | V1.1 |
| IO-Link interface type | Class A |
| Frame type | TYPE_2_V |
| Transmission rate | COM2, 38.4 kbit/s |
| ISDU (indexed service) | Supported |
| Block parameter operation | Not supported |
| Data Storage (DS) | Supported |
| Minimum cycle time | 3000 µs |
| Data storage lock | Supported (for compatibility only; the device does not execute this operation) |
| Vendor ID | 1317 (0x0525) |
| Device ID | 198162 (0x030612) |
Available measuring ranges and port sizes
| Model code | Port size | Measuring range |
|---|---|---|
| 016 | G1/2 | 1–16 L/min |
| 040 | G1/2 | 2–40 L/min |
| 070 | G1/2 | 3.5–70 L/min |
| 100 | G3/4 | 5–100 L/min |
| 150 | G1 | 9–150 L/min |