Thermal MEMS mass flow controller
Full scale from 10 mLn/min
Ranges up to 1000 mLn/min
Analog 0 ~ 5 Vdc, 4 ~ 20 mA or RS485
UNF 10-32 or 1/8” compression port
Differential pressure 0.2 MPa

Ask for a price

The MFC4200 is a thermal MEMS mass flow controller for non-corrosive gases. It measures and controls mass flow directly, without temperature or pressure compensation, and holds the setpoint with a normally closed control valve. Full scale runs from 0 ~ 10 mLn/min up to 0 ~ 1000 mLn/min — the lowest starting range of this series.

It mounts inline in the gas line and takes an analog 0 ~ 5 Vdc or 4 ~ 20 mA setpoint, or a digital RS485 command. Control pressure range is 0.1 ~ 0.8 MPa, the maximum operating differential pressure is 0.2 MPa, and the typical settling time is 100 msec.

Three values decide the variant: the full scale, the connection (UNF 10-32 female or 1/8” compression tube fitting), and the input signal. The body uses a single DB9 connector and runs from a 12 ~ 24 Vdc supply. Accuracy is ±1.0% r.d. and ±0.2% f.s.; repeatability is ±0.3% r.d. and ±0.06% f.s.

Technical data as published in the manufacturer manual (section 7).

Full-scale range0 ~ 10 mLn/min … 0 ~ 1000 mLn/min
Accuracy± 1.0% r.d. (20 ~ 100% of full scale); ±0.2% f.s. (<20% of full scale)
Repeatability± 0.3% r.d. (20 ~ 100% of full scale); ±0.06% f.s. (<20% of full scale)
Turn-down ratio100:1
Max control range102 %FS
Control pressure range0.1~0.8 MPa
Maximum operating differential pres.0.2 MPa
Setpoint source (input signal)Analog: 0~5 Vdc or 4~20 mA; Digital: RS485
Settling time (typical)100 msec
Working temperature0 ~ 55 °C
Humidity<95, no condensation %RH
Burst pressure1.5 MPa
External leakage rate≤1 x 10⁻⁹ (He) Pa·m³/s
Power supply(12 ~ 24) Vdc, 1A
Output signalAnalog: 0~5 Vdc or 4~20 mA; Digital: RS485
Max null shift (analog)±30 mVdc
Control valveNormally Closed (NC)
Electrical connectorDB9
Mechanical connectionUNF 10-32-female; compression tube fitting 1/8” or φ3
ProtectionIP40
Storage temperature-20 ~ +70 °C
Reference conditions0 °C, 101.325 kPa, air
Fluid compatibilityNon-corrosive
CEEN61000-2; -3; -4
ComplianceRoHS, REACH

RELATED PRODUCTS

MFC5100M Gas Mass Flow Controller

Thermal MEMS mass flow controller Touch screen for local setpoint Full scale 1 to 20 Ln/min Repeatability ±0.5% r.d. / ±0.1% f.s. M12 or DB9 electrical connector VCR 1/4” or BSPT 1/8” female port

MFC5000 Gas Mass Flow Controller

Thermal MEMS mass flow controller Full scale 2 to 20 SLPM DeviceNet, RS485 Modbus, analog output VCR or BSPT 1/8” to 1/2” female M12 and DB9 electrical connectors Max pressure loss 20 kPa at 20 SLPM

MFC2000 Gas Mass Flow Controller

Thermal MEMS mass flow controller Full scale 50 mLn/min to 200 Ln/min Largest span in the MFC series Analog 0 ~ 5 Vdc, 4 ~ 20 mA or RS485 Control pressure 0.1 ~ 0.8 MPa 7/16-20UNF to VCR 1/2” connections

MFC1600 Gas Mass Flow Controller

Thermal MEMS mass flow controller Full scale 50 mLn/min to 100 Ln/min Accuracy ±1.5% r.d. over 20 ~ 100% FS Control pressure 0.1 ~ 0.8 MPa Analog 0 ~ 5 Vdc or RS485 setpoint G 1/4” ~ 3/8” or quick-twist fitting

RELATED PRODUCTS