MEMS thermal mass flow controller
Full scale 50 to 500 mLn/min
Turn-down ratio 100:1
Normally closed control valve
UNF 10-32 female connection
45 x 45.5 x 20 mm body

Ask for a price

Tag:

The MFC4000 is a miniature thermal MEMS mass flow controller for non-corrosive gases. It measures and controls mass flow directly, without temperature or pressure compensation, and holds the setpoint with a normally closed control valve. Full scale runs from 0 ~ 50 mLn/min up to 0 ~ 500 mLn/min.

It mounts inline in the gas line through UNF 10-32 female ports and takes an analog 0 ~ 5 Vdc or 4 ~ 20 mA setpoint, or a digital RS485 command. Control pressure range is 0.1 ~ 0.8 MPa with a maximum operating differential pressure of 0.4 MPa, the settling time is 100 msec, and maximum pressure loss is 22 kPa on the 500 mLn/min models.

Three values decide the variant: the full scale, the input signal (analog 0 ~ 5 Vdc, 4 ~ 20 mA or digital RS485), and the electrical interface — a single DB9 connector, with 8 ~ 24 Vdc supply. Accuracy is ±1.0% r.d. and ±0.2% f.s.; repeatability is ±0.3% r.d. and ±0.06% f.s.

Technical data as published in the manufacturer manual (section 7).

Full-scale range0 ~ 50 mLn/min … 0 ~ 500 mLn/min
Accuracy± 1.0% r.d. (20 ~ 100% of full scale); ±0.2% f.s. (<20% of full scale)
Repeatability± 0.3% r.d. (20 ~ 100% of full scale); ±0.06% f.s. (<20% of full scale)
Turn-down ratio100:1
Max control range102 %FS
Control pressure range0.1 ~ 0.8 MPa
Maximum operating differential pressure0.4 MPa
Setpoint source (input signal)Analog: 0 ~ 5 Vdc or 4 ~ 20 mA; Digital: RS485
Settling time100 msec
Working temperature0 ~ 55 °C
Humidity<95, no condensation %RH
Burst pressure1.5 MPa
Max pressure loss22 (500 mLn/min models) kPa
External leakage rate (He)≤1 * 10⁻⁹ Pa·m³/s
Power supply8 ~ 24 Vdc
Output signalAnalog: 0 ~ 5 Vdc or 4 ~ 20 mA; Digital: RS485
Max null shift (analog)±30 mVdc
Control valveNormally Closed (NC)
Electrical connectorDB9
Mechanical connectionUNF 10-32-female
ProtectionIP40
Storage temperature-20 ~ +70 °C
Reference conditions0 °C, 101.325 kPa, air
Fluid compatibilityNon-corrosive
CEEN61000-2; -3; -4
EnvironmentalRoHS, REACH

RELATED PRODUCTS

MF4700 Gas Mass Flow Meter

MEMS thermal mass flow meter, NPT or BSPT
Maximum overflow 6 to 2000 SLPM by model
Accuracy ±(2.0+0.5FS) %
Analog 0.5 to 4.5 Vdc or 4 to 20 mA
RS485 Modbus half-duplex output
IP40 body, AMPMODU MTE or M8 connector

MF4600 Gas Mass Flow Meter

MEMS thermal mass flow meter, DN1 to DN8
Maximum overflow 2 to 200 SLPM by model
Accuracy ±(2.0+0.5FS) %
Analog 0.5 to 4.5 Vdc or 4 to 20 mA
RS485 Modbus half-duplex output
IP40 body with manual keypad control

MF4500 Gas Mass Flow Meter

MEMS thermal mass flow meter, BSPT inline
MF4512 100 to 300 SLPM, MF4519 500 to 1000 SLPM
Accuracy ±(2.0+0.5FS) %
Turn-down ratio 50:1
RS485 Modbus half-duplex output
IP40 body, BSPT 1/2 and 3/4 inch connections

MF4000 Gas Mass Flow Meter

MEMS thermal gas mass flow meter
Full scale 2 to 50 SLPM (MF4003 / MF4008)
Accuracy ±(1.5+0.15FS) %
Turn-down ratio 100:1
Analog 1 to 5 Vdc plus RS485 / RS232 / I2C
IP40 body, BSPT or 4 / 6 / 8 mm one-touch

RELATED PRODUCTS