Direct gas mass flow measurement
Flow range 0 ~ 100 or 0 ~ 150 SLPM
Accuracy ±(2.0+0.5FS) % total error band
I2C and analog 0.5 ~ 4.5 Vdc output
1300 Pa pressure drop at 150 SLPM
8 msec response, 100:1 turn-down ratio

Ask for a price

Tag:

The FS1015E is a MEMS thermal mass flow sensor for gases. It measures mass flow directly, without temperature or pressure compensation, and reports the result as an analog output of 0.5 ~ 4.5 Vdc or over I2C. It runs from 5±5% Vdc and draws about 10 mA with no output load.

The sensor sits inline in the gas line, so the full flow passes through the measuring channel. A 100:1 turn-down ratio and an 8 msec response time let it follow both the main flow and the small flows around it; pressure drop at full scale is 1300 Pa at 150 SLPM.

Three values decide the variant: the flow range (0 ~ 100 or 0 ~ 150 SLPM), the output (I2C or analog 0.5 ~ 4.5 Vdc), and the error band you can accept, ±(2.0+0.5FS) % with a repeatability of (0.5+0.15FS) %.

Technical data as published in the manufacturer datasheet.

Flow range0 ~ 100, 0 ~ 150 SLPM
Accuracy (total error band)±(2.0+0.5FS) %
Repeatability(0.5+0.15FS) %
Turn-down ratio100:1
Response time8 msec
Working temperature-10 ~ +55 °C
Temperature coefficient±0.12 %/°C
Maximum pressure0.2 MPa
Pressure drop at full scale1300 (150 SLPM) Pa
Humidity<95 (no condensation) %RH
Analog null shift±30 mVdc
Power supply5±5% Vdc
Working current~10 (no output load) mA
OutputLinear, Analog: 0.5 ~ 4.5 Vdc, I2C
Analog output loadSourcing: 25; Sinking: 15 mA
Maximum overflow300 SLPM
Maximum flow change40 SLPM/sec
Storage temperature-20 ~ +70 °C
Weight21.5 g with ISO connector
CalibrationAir @ 20°C, 101.325kPa
ComplianceRoHS; REACH
CEIEC 61000-4-2;4;8

RELATED PRODUCTS

MF4700 Gas Mass Flow Meter

MEMS thermal mass flow meter, NPT or BSPT
Maximum overflow 6 to 2000 SLPM by model
Accuracy ±(2.0+0.5FS) %
Analog 0.5 to 4.5 Vdc or 4 to 20 mA
RS485 Modbus half-duplex output
IP40 body, AMPMODU MTE or M8 connector

MF4600 Gas Mass Flow Meter

MEMS thermal mass flow meter, DN1 to DN8
Maximum overflow 2 to 200 SLPM by model
Accuracy ±(2.0+0.5FS) %
Analog 0.5 to 4.5 Vdc or 4 to 20 mA
RS485 Modbus half-duplex output
IP40 body with manual keypad control

MF4500 Gas Mass Flow Meter

MEMS thermal mass flow meter, BSPT inline
MF4512 100 to 300 SLPM, MF4519 500 to 1000 SLPM
Accuracy ±(2.0+0.5FS) %
Turn-down ratio 50:1
RS485 Modbus half-duplex output
IP40 body, BSPT 1/2 and 3/4 inch connections

MF4000 Gas Mass Flow Meter

MEMS thermal gas mass flow meter
Full scale 2 to 50 SLPM (MF4003 / MF4008)
Accuracy ±(1.5+0.15FS) %
Turn-down ratio 100:1
Analog 1 to 5 Vdc plus RS485 / RS232 / I2C
IP40 body, BSPT or 4 / 6 / 8 mm one-touch

RELATED PRODUCTS