Product categories
MF5806-G Gas Cylinder Mass Flow Meter
Mass flow meter for gas cylinders, 20 or 50 L/min
M16x1.5 connection to the cylinder regulator
Accuracy ±(2.0+0.5FS) %, turn-down ratio 80:1
4 x AA batteries or 5 ~ 24 Vdc, USB Type-C port
RS485 Modbus, LoRa, WiFi, NB-IoT or BT LE
Pressure loss 2.0 kPa at 50 SLPM, IP50, 0.8 MPa
MF5806-G is a gas cylinder mass flow meter that fits between the cylinder regulator and the gas line, with readings referred to 20 °C and 101.325 kPa. It covers 0 ~ 20 and 0 ~ 50 L/min and takes air, N2, O2, Ar and CO2.
Three values decide the order: the full-scale range, the connection to the regulator, and the output. The body is machined for an M16x1.5 regulator thread with the cylinder seal specified by the customer, so different cylinder standards can be covered. Output is RS485 Modbus half-duplex, with LoRa, WiFi, NB-IoT or Bluetooth LE available as wireless options.
Accuracy is ±(2.0+0.5FS) % with (0.5+0.15FS) % repeatability, turn-down ratio 80:1 and response time below 2.0 sec. Maximum overflow is 100 L/min, maximum flow change 15 L/min/sec and pressure loss 2.0 kPa at 50 SLPM. The meter runs on 4 x AA batteries or 5 ~ 24 Vdc through a USB Type-C port, resolution is 0.01 L/min, maximum pressure is 0.8 MPa and protection is IP50.
Technical data as published in the manufacturer manual (section 7).
| Full-scale flow range | 0 ~ 20; 0 ~ 50 L/min |
|---|---|
| Accuracy | ±(2.0+0.5FS) % |
| Repeatability | (0.5+0.15FS) % |
| Turn-down ratio | 80:1 |
| Response time | <2.0 sec |
| Working temperature | -10 ~ +55 °C |
| Maximum pressure | 0.8 MPa |
| Humidity | <95, no condensation %RH |
| Maximum overflow | 100 L/min |
| Maximum flow change | 15 L/min/sec |
| Pressure loss @ 50SLPM | 2.0 kPa |
| Power supply | 4-AA batteries (LR6) / 5 ~ 24 Vdc |
| Power consumption | >60 (on batteries) day |
| Power/data interface | USB Type-C |
| Digital output | RS485 Modbus half-duplex |
| Wireless options | LoRa / WIFI / NB-IoT / BT LE |
| Display | LCD |
| Resolution | 0.01 L/min (instant) / 0.001 m3 (accumulated) |
| Mechanical connection | Gas cylinder connection (customizable) |
| Storage temperature | -20 ~ +70 °C |
| Reference conditions | 20°C, 101.325 kPa, air |
| Protection | IP50 |
| Fluid compatibility | Non-corrosive |
| CE | EN61326-1; -2; -3 |