Product categories
MF-GD Gas Mass Flow Meter
Flanged gas mass flow meter for utility gas
Battery 2x D-Cell 19 Ah or 8 ~ 12 Vdc supply
Accuracy ±(1.5+0.25FS) %, turn-down 100:1
Battery life over 36 months, RTC life over 10 years
Ex ia IIC T4 Gb, enclosure IP66 (NEMA 4x)
RS485 Modbus half-duplex or pulse output
MF-GD is a flanged gas mass flow meter built for city utility gas metering, and it also serves general-purpose low-pressure gas metering. MEMS calorimetric sensing identifies the thermal properties of the gas while it flows, so the meter adjusts itself between air and natural gas and no gas conversion factor has to be entered by hand.
The flow channel is arranged as a semi-Venturi with the sensing elements at its centre, which keeps sensitivity at low flow while the dynamic range stays wide for tariff metering. Gas temperature may reach -20 ~ +55 °C at pressures up to 0.6 MPa; the enclosure is IP66 (NEMA 4x) and the meter is approved as Ex ia IIC T4 Gb.
It runs from two D-Cell 19 Ah lithium cells or from an 8 ~ 12 Vdc supply. Battery life is more than 36 months and the real-time clock runs more than 10 years. Digital output is RS485 Modbus half-duplex or pulse, with the menu reached through three front-face keys. For selection, check the full-scale flow rate against the model table, the flange size, and the output signal; accuracy is ±(1.5+0.25FS) %.
Technical data as published in the manufacturer manual (section 7).
| Full-scale flow range | See Table 6.1 |
|---|---|
| Accuracy | ±(1.5+0.25FS) % |
| Repeatability | (0.5+0.08FS) % |
| Turn-down ratio | 100:1 |
| Working temperature | -20 ~ +55 °C |
| Maximum pressure | 0.6 MPa |
| Humidity | <95, no condensation %RH |
| Power supply | 2x D-Cell 19 Ah lithium-ion or 8 ~ 12 Vdc |
| Battery life | >36 Months |
| Real-time clock life | >10 Years |
| Digital output | RS485 Modbus half-duplex / Pulse |
| MENU access | 3 key – front face keyboard/digital |
| Display | LCD, instant flow rate, totalizer, or accumulated flow rate |
| Storage temperature | -20 ~ +70 °C |
| Reference conditions | 20°C, 101.325 kPa, air |
| Protection | IP66 (NEMA 4x) |
| Fluid compatibility | Non-corrosive |
| Ex Proof | Ex ia IIC T4 Gb |