Product categories
MF-HD Gas Flow Meter
Battery-powered gas flow meter for LPG and gas
MF19HD and MF25HD, 0.016 to 36 m3/h ranges
Class 1.5 on LPG, ±(1.5 r.d.+0.25 FS) % on gas
Ex ib IIB T4 Gb hazardous rating, IP66
RS485 Modbus, Bluetooth LE or customized
3.6 V 19 Ah lithium battery, 5 years standby
MF-HD is a battery-powered gas flow meter for utility metering of natural gas and LPG, including cylinder management in residential energy supply. The two body sizes, MF19HD and MF25HD, cover LPG ranges from 0.016 to 16 m3/h and air, nitrogen, oxygen, argon and methane ranges from 0.06 to 36 m3/h, with the matching SCFH figures in the model tables.
Metering uses MEMS thermal sensing at low pressure drop. Working pressure is 50 ~ 150 kPa, burst pressure 300 kPa, and gas temperature may run from -40 to +60 °C. The enclosure is IP66 and the battery-powered models carry the hazardous rating Ex ib IIB T4 Gb. A 3.6 V, 19 Ah lithium cell gives five years minimum without communication, three years in Bluetooth LE Beacon mode and six months in Master-slave mode; battery life depends on use and is about ten years in standard LPG cylinder service.
Data leaves the meter over RS485 Modbus, Bluetooth LE or a customized interface. Selection looks at the gas and its full-scale flow rate, the connection thread, and the data interface; accuracy is Class 1.5 on LPG and ±(1.5 r.d.+0.25 FS) % on the other gases.
Technical data as published in the manufacturer manual (section 7).
| Flow range (LPG, MF19HD-G1.6) | 0.016 ~ 2.5 m3/h / 0.5 ~ 90 SCFH |
|---|---|
| Flow range (LPG, MF25HD-G2.5) | 0.025 ~ 4.0 m3/h / 0.8 ~ 142 SCFH |
| Flow range (LPG, MF25HD-G4) | 0.04 ~ 6.0 m3/h / 1.4 ~ 212 SCFH |
| Flow range (LPG, MF25HD-G6) | 0.06 ~ 10 m3/h / 2.5 ~ 400 SCFH |
| Flow range (LPG, MF25HD-G10) | 0.10 ~ 16 m3/h / 4.0 ~ 600 SCFH |
| Flow range (Air, N2, O2, Ar, CH4, MF19HD-6) | 0.06 ~ 6 m3/h (=1.0 ~ 100 SLPM) / 2 ~ 200 SCFH |
| Flow range (Air, N2, O2, Ar, CH4, MF25HD-10) | 0.10 ~ 10 m3/h (= 1.6 ~ 160 SLPM) / 4.0 ~ 400 SCFH |
| Flow range (Air, N2, O2, Ar, CH4, MF25HD-15) | 0.15 ~ 15 m3/h (= 2.5 ~ 250 SLPM) / 6.0 ~ 600 SCFH |
| Flow range (Air, N2, O2, Ar, CH4, MF25HD-24) | 0.24 ~ 24 m3/h (= 4 ~ 400 SLPM) / 8.0 ~ 800 SCFH |
| Flow range (Air, N2, O2, Ar, CH4, MF25HD-36) | 0.36 ~ 36 m3/h (= 6 ~ 600 SLPM) / 12 ~ 1200 SCFH |
| Turn-down ratio (LPG) | 160:1 |
| Turn-down ratio (Air, N2, O2, Ar, CH4) | 100:1 |
| Accuracy (LPG) | Class 1.5 |
| Accuracy (Air, N2, O2, Ar, CH4) | ±(1.5 r.d.+0.25 FS) % |
| Working temperature | -40 ~ +60 °C |
| Working pressure | 50 ~ 150 kPa |
| Burst pressure | 300 kPa |
| Power supply | Lithium-ion battery 3.6 V, 19 Ah (5 years minimum without communication; 3 years with Bluetooth LE, Beacon mode; 6 months with Bluetooth LE, Master-slave mode); external power supply 8 ~ 24 Vdc (RS485 and Bluetooth LE, Beacon mode or Master-slave mode). Battery life depends on usage and environment; about 10 years for standard LPG cylinder applications |
| Display resolution, instant flow rate (MF19HD-G1.6) | 0.0001 m3/h or 0.001 SCFH |
| Display resolution, instant flow rate (MF19HD-6) | 0.0001 m3/h or 0.01 SCFH |
| Display resolution, instant flow rate (MF25HD-G2.5/G4) | 0.0001 m3/h or 0.01 SCFH |
| Display resolution, instant flow rate (MF25HD-10/15/24) | 0.001 m3/h or 0.01 SCFH |
| Display resolution, instant flow rate (MF25HD-G6/G10) | 0.001 m3/h or 0.01 SCFH |
| Display resolution, instant flow rate (MF25HD-36) | 0.001 m3/h or 0.1 SCFH |
| Display resolution, totalized flow rate | 0.001 m3 or 0.01 SCF |
| Data interface | RS485 Modbus, Bluetooth LE, or customized |
| Reference conditions | 20°C, 101.325 kPa, air |
| Storage temperature | -30 ~ +70 °C |
| Hazardous rating | Ex ib IIB T4 Gb (battery-powered models) |
| Protection | IP66 |
| Gas compatibility | Noncorrosive (for other gases, contact the manufacturer) |
| CE | EN61326-1 |