MF3000 Gas Mass Flow Meter
MEMS thermal mass flow meter, M / S / V body
Full scale 2 to 1500 SLPM on air, N2, O2, Ar
Accuracy ±(2.5+0.5FS) %
Response time 10 msec
RS485 Modbus or I2C digital output
Analog 4 to 20 mA, 1 to 5 Vdc, NPN or PNP
MF3000 is a MEMS thermal gas mass flow meter offered in three body styles. The MF3000M and MF3000S share one full-scale set running from 2 to 1500 SLPM on air, N2, O2 and Ar, with real CO2 calibration on units up to 100 SLPM; the MF3000V covers the larger 50 to 200 SLPM span. Both CO2 lines are quoted separately in the manual.
Accuracy is ±(2.5+0.5FS) % over a 50:1 turn-down ratio, response time is 10 msec, and the temperature coefficient is ±0.12 %/°C between -10 and +55 °C. Working pressure is 0.8 MPa.g and the filter depth is set to 3 by default, programmable from 0 to 9. Digital output is RS485 Modbus or I²C; Output 2 adds analog 4 to 20 mA, 1 to 5 Vdc, NPN or PNP, and Output 3 carries NPN and PNP. The meter runs from 8 to 24 Vdc at 50 mA and terminates in an HRS DF51K-6P-2DS connector.
To specify a unit, fix the full-scale flow rate for your gas, the body style that fits the installation, and the output the controller accepts. Maximum overflow and maximum flow change scale with the selected full scale, as listed in the table.
Technical data as published in the manufacturer manual (section 7).
| Full-scale flow range (MF3000M, MF3000S, air, N2, O2 and Ar) | 2, 5, 10, 20, 50, 100, 200, 500, 1000, 1500 SLPM |
|---|---|
| Full-scale flow range (MF3000M, MF3000S, CO2) | 2, 5, 10, 20, 50, 100, 200, 500, 800 SLPM, real CO2 gas calibration for models <= 100 SLPM |
| Full-scale flow range (MF3000V, air, N2, O2 and Ar) | 50, 100, 200 SLPM |
| Full-scale flow range (MF3000V, CO2) | 50, 100 SLPM |
| Accuracy | ±(2.5 + 0.5FS) % |
| Repeatability | (0.8+0.15FS) % |
| Turn-down ratio | 50:1 |
| Working temperature | -10 ~ +55 °C |
| Temperature coefficient | ±0.12 %/°C |
| Working pressure | 0.8 MPa.g |
| Response time | 10 msec |
| Filter depth | 3 (default, 0 … 9 programmable) |
| Humidity | <95, no condensation %RH |
| Power supply | 8 ~ 24 (50 mA) Vdc |
| Output 1 (Digital output) | RS485 Modbus or I²C |
| Output 2 | Analog 4 ~ 20 mA, 1 ~ 5 Vdc, NPN, PNP |
| Output 3 | NPN, PNP |
| Null shift (1 ~ 5 Vdc output) | ±30 mVdc |
| Max. overflow (models 2, 5 SLPM) | 30 SLPM |
| Max. overflow (models 10, 20 SLPM) | 100 SLPM |
| Max. overflow (model 50 SLPM) | 200 SLPM |
| Max. overflow (models 100, 200 SLPM) | 500 SLPM |
| Max. overflow (models 500, 1000, 1500 SLPM) | 2000 SLPM |
| Max. flow change (models 2, 5 SLPM) | 4 SLPM/sec |
| Max. flow change (models 10, 20 SLPM) | 15 SLPM/sec |
| Max. flow change (model 50 SLPM) | 30 SLPM/sec |
| Max. flow change (models 100, 200 SLPM) | 100 SLPM/sec |
| Max. flow change (models 500, 1000, 1500 SLPM) | 400 SLPM/sec |
| Electrical connector | HRS: DF51K-6P-2DS |