Product categories
GL-400 Submersible Liquid Level Transmitter
Submersible level and temperature, one probe
0–2 … 10 mH₂O measuring range
Accuracy up to ±0.05 %FS (0–10 mH₂O)
RS485 Modbus-RTU, 9–30 VDC supply
Ceramic capacitive element, 5 × FS overload
316L or TC4 titanium housing, IP68, Ø25 mm
The GL-400 is a submersible level transmitter for water level and water temperature in shallow water and open tanks. A dry ceramic capacitive element measures the hydrostatic head; the same probe records the water temperature, so both readings refer to the same point in the tank.
Full-scale digital linearisation and temperature compensation are applied across the whole compensation range, and the coefficients are stored in non-volatile memory. Supply monitoring and a watchdog keep a permanently installed unit at its calibration state and bring it back automatically after a power failure. Level and temperature travel to the controller over one RS485 Modbus-RTU cable.
Measuring ranges run from 0–2 to 10 mH₂O. The 316L or TC4 titanium housing is fully sealed to IP68, so the probe stays submerged in service, and the ceramic element carries 5 × full-scale overload. Typical users are hydrological observation stations, water utilities and environmental monitoring projects.
| Accuracy (TEB.) | ±0.25 %FS (0–2 mH₂O); ±0.05 %FS (0–10 mH₂O) |
|---|---|
| Range | 0–2 mH₂O … 10 mH₂O |
| Long-term stability | < 0.05 %FS/year |
| Overload capability | 5 × FS |
| Temperature accuracy | ±0.2 °C (0–70 °C) |
| Temperature resolution | 0.05 °C |
| Compensation temperature | 0–70 °C |
| Operating temperature | −10–80 °C |
| Drift of temperature | Zero: < 0.005 %FS/°C; F.S.: < 0.005 %FS/°C |
| Storage temperature | −40–125 °C |
| Power supply | 9–30 VDC (typ. 24 V) |
| Power protection | Reverse polarity and over-voltage protection |
| Output | RS485 / Modbus-RTU |
| Seal material | FKM |
| Sensor material | Alumina ceramic, gold-plated |
| Housing material | Stainless steel 316L or titanium alloy TC4 |
| Cable material | Polyurethane or PVC |
| Cable | Ø7.6 mm, shielded, length customized |
| Protection level | IP68 |
| Insulation | 100 MΩ @ 50 V |
Cable definition
| V+ | Red |
|---|---|
| GND | Yellow |
| RS485A | Blue |
| RS485B | Green |
Order guide
| Code1 · Measuring range | [0~X] mH₂O, X = 2 … 10 |
|---|---|
| Code2 · Output signal | R1 — RS485 / Modbus-RTU |
| Code3 · Material of structural components | SS — 316L housing & process connection; TC — TC4 housing & process connection |
| Code4 · Cable material | PU — Polyurethane; PV — PVC |
| Code5 · Cable length | L — cable length in m, e.g. L10 = 10 m |
| Example | GL-400-[0-10]mH₂O-R1-SS-PU-L10 |